Description

errore LI_SlowRampSteer - calcRefCurve: indice oltre i limiti della matrice

errore2.JPG View (191 KB) Marco Pesce, 05/30/2023 04:43 PM

H2305_23.zip (2.66 MB) Marco Pesce, 06/08/2023 04:54 PM

Immagine 2023-06-13 153221.png View - Stato manovra non "Ready" a inizio attuazione (76.5 KB) Marco Pesce, 06/13/2023 03:42 PM

History

#1 Updated by Marco Pesce over 2 years ago

  • File errore2.JPG View added
  • File H2305_23.zip added
  • Description updated (diff)
  • Cliente set to 2
  • Strumento set to 16
  • Serial Number Strumento set to D023DC5029

#2 Updated by Marco Pesce over 2 years ago

  • Versione HRB set to 1.18.1

#3 Updated by Marco Pesce over 2 years ago

  • File deleted (H2305_23.zip)

#4 Updated by Marco Pesce over 2 years ago

#5 Updated by Marco Pesce over 2 years ago

Problema dovuto all'inizio dell'attuazione volante prima che la manovra fosse in stato "Ready" (immagine allegata).
Di conseguenza l'inizio manovra viene identificato alla fine del riallineamento e i parametri non sono significativi.
In HRB รจ stato introdotto un controllo per prevenire il messaggio di errore, e la manovra viene indicata come non valida.

#6 Updated by Marco Pesce over 2 years ago

  • Due date set to 06/13/2023
  • % Done changed from 0 to 100